جدول مقدار آمپر براي متراز كابل هاي مختلف در دما هاي مختلف ضريب گرما در نظر گرفته شود
| مسافت | 10 | 50 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 450 | 500 | 600 |
سطح مقطع | | * | * | * | * | * | * | * | * | * | * | * | * |
1.5 | | 27A | 27A | 7A | 5A | * | * | * | * | * | ** | * | * |
2.5 | | 36A | 36A | 12A | 8A | 6A | * | * | * | * | * | * | * |
4 | | 46A | 46A | 20A | 13A | 10A | 8A | 6A | * | * | * | * | * |
6 | | 58A | 58A | 30A | 20A | 15A | 12A | 10A | 8A | 7A | 6.5A | 6A | 5A |
10 | | 77A | 77A | 50A | 33A | 25A | 20A | 16A | 14A | 12A | 11A | 10A | 8A |
16 | | 100A | 100A | 80A | 53A | 40A | 32A | 26A | 22A | 20A | 17A | 16A | 13A |
25 | | 130A | 130A | 125A | 83A | 62A | 50A | 41A | 35A | 31A | 27A | 25A | 20A |
35 | | 155A | 155A | 155A | 115A | 86A | 69A | 57A | 49A | 43A | 38A | 34A | 28A |
50 | | 185A | 185A | 185A | 156A | 117A | 93A | 78A | 66A | 58A | 52A | 46A | 38A |
70 | | 230A | 230A | 230A | 222A | 166A | 133A | 114A | 95A | 83A | 74A | 66A | 55A |
95 | | 175A | 175A | 275A | 275A | 225A | 180A | 150A | 129A | 117A | 100A | 90A | 75A |
120 | | 315A | 315A | 315A | 315A | 275A | 222A | 185A | 159A | 139A | 123A | 111A | 92A |
150 | | 355A | 355A | 355A | 355A | 330A | 264A | 220A | 189A | 165A | 147A | 132A | 110A |
185 | | 400A | 400A | 400A | 400A | 393A | 314A | 262A | 220A | 196A | 174A | 157A | 131A |
© کپی رایت توسط .:مقاله نت.: بزرگترين بانك مقالات دانشجويي کلیه حقوق مادی و معنوی مربوط و متعلق به این سایت و گردآورندگان و نويسندگان مقالات است.)